TM5-6115-640-14&P
Power Plants AN/MJQ-32 and AN/MJQ-33 each have two MEP-701A generator sets.
Replacement procedures for either generator set are identical for both power plants, except where noted.
a.
Removal.
(1)
Remove tarpaulin from AN/MJQ-33 (paragraph 3-6a(1)).
(2)
Remove four bow assemblies from AN/MJQ-33 (paragraph 3-6b(1)).
(3) Remove ground wires from generator set ground stud (1, figure 5-1).
(4)
Open service access door (2), and disconnect all load cables (3) and remove from generator set (4). Close
access door.
(5)
Remove four screws (5), eight washers (6), and four locknuts (7) securing generator set (4) to trailer bed (8).
(6)
Remove engine oil drain hose (9) from grommet in AN/MJQ-33 trailer bed.
(7)
Disconnect auxiliary fuel line (10), if connected.
WARNING
When lifting generator set, use lifting equipment with a minimum lifting capacity of 1500 lb. Do
not stand under generator while it is being lifted. Failure to observe these precautions can case
death or injury to personnel or damage to equipment.
(8)
Open lifting eye access door (1, figure 5-2) and attach lifting equipment with a minimum lifting capacity of 1500
lb (2) to lifting eye (3) on top of generator set (4) and remove generator set from trailer.
b.
Installation.
WARNING
When lifting generator set, use lifting equipment with a minimum lifting capacity of 1500 lb. Do
not stand under generator while it is being lifted. Failure to observe these precautions can cause
death or injury to personnel or damage to equipment.
5-2