TM 5-6115-365-15
C2
Section II. OPERATING INSTRUCTIONS
6-3. Setting-up Instructions
a.
Leveling.
(1)
Locate the trailer on as level a surface as
possible in order for the generator set to operate as
efficiently as possible.
(2)
Set brakes and block wheels securely to
prevent any movement. Operate handbrake at weekly
intervals to insure freedom of linkage.
(3)
Pull leg prop down and adjust length for
firm contact with ground.
WARNING
Wheels must be blocked, brakes set,
and leg prop down in the support
position before attempting to roll up
the tarpaulin and before starting to
assemble or set up the equipment for
operation.
b.
Preparation for Starting.
(1)
Remove the canvas tarpaulin and remove
the roof bows and racks as shown in figure 6-2.
(2)
Open the trailer tailgate and remove all
loose auxiliary items and anything else that might block
the free circulation of air through the trailer and around
the generator sets.
CAUTION
It is of foremost importance that
there be free circulation of air around
the generator sets at all times during
operation.
WARNING
Never operate the generator set in an
enclosed area unless the exhaust
gases are piped to the outside.
Inhalation of exhaust fumes will
result in serious illness or death.
c.
Grounding.
WARNING
Never operate the generator set until
it
has
been
properly
grounded.
Electrical defects in the load lines or
equipment
can
cause
death
by
electrocution when contact is made
with an ungrounded system.
(1)
The generator set must be grounded prior
to operation. The ground may be any of three methods,
depending on the location and the terrain.
(a)
A ground rod driven to a depth of 8
feet.
(b)
An
underground
metallic
water
piping system.
(c)
A metal plate (9 square ft.) buried to
a depth of 4 feet.
(2)
The ground lead must be No. 6 AWG
copper wire bolted or clamped to the rod, plate, or piping
system.
(3)
Connect the other end of the ground lead
to the trailer ground terminal stud as shown in figure 6-3.
6-4. Starting
a.
Perform pre-starting and setting-up procedures
(para 6-3).
b.
Start
the
generator
as
instructed
in
TM 5-6115-332-12.
6-5. Stopping
Stop
the
generator
set
as
instructed
in
TM 5-6115-332-12.
6-6. Operation
a.
Operate the generator set as instructed in
TM 5-6115-332-12.
b.
Perform the fuel transfer procedure as instructed
in figure 6-4.
6-3