TB 9-6115-643-13
This task covers:
a. Inspect
d. Repair
b. Test
e. Replace
c. Remove
f. Install
INITIAL SETUP
Equipment Conditions
Tools
Tool Kit, General Mechanic's
Reference
Generator shut down, TM 9-6115-643-10, Paragraph 2-9.2
Materials/Parts
None
WARNING
Do not attempt any tasks inside generator housing with generator set
running. Failure to observe this warning could result in severe personal
injury or death.
INSPECTION
Inspection is limited to visual inspection of components. Check for damaged and frayed wiring.
TEST
Test wiring for continuity (refer to Figure 4-27). Replace any open or broken wires or connectors.
REMOVAL
1.
Prior to removal, refer to Figure 4-27 and tag all leads on wiring harness.
2.
Disconnect all leads and plugs. Remove wiring harness.
REPAIRMENT
Repair consists of replacing wires, connectors, and terminals. Follow standard shop practice when performing all repairs.
REPLACEMENT
1.
Perform steps 1 thru 2 of removal.
2.
Perform steps 1 thru 2 of installation, substituting new wiring harness for the defective one.
INSTALLATION
1.
Position wiring harness in place.
2.