TB 9-6115-643-13
This task covers:
a. Replace
INITIAL SETUP
Tools
Equipment Conditions
Tool Kit, General Mechanic's
Reference
Generator shut down, TM 9-6115-643-10, Paragraph 2-9.2
Materials/Parts
REPLACE
WARNING
Disconnect negative battery cable from right battery and the positive
battery cable from the left battery before doing the following
procedures. Failure to observe this warning could result in severe
personal injury or death.
WARNING
Catch fuel in a suitable container. Keep spilled fuel away from hot
engine and all fires, and wash with warm water after getting any on
skin. Fuel is highly flammable and is irritating to skin.
1.
Turn heater and generator off.
2.
Open left and right access doors and disconnect negative battery cable from right battery and positive battery cable
from the left battery.
3.
Support heater. Remove screws (1, 3, 4), Figure 4-23, washers (2, 7, and 8), nut (11), lock washers (5, 6, and 9) and
heater from heater-mounting brace (10), then heater-mounting brace (10) from wall-mounting bracket (12), and
wall-mounting bracket (12) and screws (13) from generator housing (14).
4.
Inspect all hardware (1-13) for damage and replace as required.
5.
Install wall-mounting bracket (12) with screws (4, 13), lock washers (6) and washers (8) to generator housing (14).
6.
Install heater to heater-mounting brace (10) with screws (1), washers (2), lock washers (9) and nut (11).
7.
Install heater-mounting brace (10) to wall-mounting bracket (12) with screws (3), lock washers (5), and washers (7).
8.
Reconnect batteries and close access doors.