TB 11-6115-741-24
Figure 1 BATTERY CONNECTION INSTRUCTION PLATE
2 Remove wire # 310B16 from the positive terminal of the NATO slave receptacle (SR1) as shown in
figure 2.
Wire # 310B16
Figure 2 Battery Compartment
3 Disconnect wire #310B16 from the positive terminal on the battery charging alternator, cut off
the terminal lug and remove the wire and fuse holder from the harness, see figure 3. If wire
#165C16 has not been removed from the current transformer, perform the procedure in appendix
A to move the DC control power wire.
6-9