ARMY TM 9-6115-643-10
AIR FORCE TO 35C2-3-445-21
1-7.18. Oil Filter (7). The oil filter is located in the engine
compartment on the right side. The filter removes
1-7.23 Convenience
Receptacle (10).
The
convenience receptacle is a 10 Amp, 120 VAC
receptacle used to operate small plug in type equipment.
1-7.19 Fan Belt (19). The fan belt is located in the
It is protected by a Ground
Fault Circuit Interrupter
engine compartment on the front of the engine. The belt
located below the Malfunction Indicator (17.12), an
drives the fan, water pump and battery charging
Overload Circuit Breaker located inside the control
box, and an inline fuse on generator sets, contract
number DAAKO188DD082. The convenience receptacle
1-7.20 Water Prin. (20). The water pump is located in
power is available at all times during operation of the
the engine compartment on the front of the engine.
generator set.
The pump circulates the engine coolant through the
engine block and the radiator.
1-8
DIFFPRRNCES BETWEEN MODELS.
The differences between models of the generator sets
covered in this manual are as follows:
1-7.21 Dead Crank Switch (6). The Dead Crank switch
is located in the engine compartment on the right side.
Model 50/60 Hz is equipped with a 50/60 Hz generator
The switch allows the engine to be cranked without
starting for maintenance purposes.
Model 400 Hz is equipped with a 400 Hz generator
1-7.22 Paralleling Receptacle (11). The Paralleling
1-9
RQUIPMFNT DATA.
For a list of Leading
receptacle is
used
to
connect
the paralleling
cable between two generator sets of the same size and
mode
to
operate
in
parallel.
Table 1-1. Leading Particulars
1.
Generator Set:
Model Numbers
15kW 50/60 Hz Tactical Quiet
MEP-804A
15kW 400 Hz Tactical Quiet
MEP-814A
National Stock Numbers
15kW 50/60 Hz Tactical Quiet
15kW 400 Hz Tactical Quiet
Overall Length
MEP-804A
69.7 in. (177.2 cm)
MEP-814A
69.7 in. (177.2 cm)
Change 3
1-7