TM 9-6150-228-13&PG.2GENERALINFORMATION-CONTINUED.Table G-2. Crimp ToolsItem No.NomenclatureSizePart Numbers1Removal Tool, Pin/Socket M81969/27-31MS90562-32Removal tool, pin/socket4TP201315-043Removal tool, pin/socket M81969/2746MS90562-64Installer tool, pin/socket4M81969/17-075Crimp tool system, pneumatic 400-1-200-5KL-M25520/23-015aLocator, pin/socket 4297-54M22520/23-125bCrimping die, pin/socket 414DA-4N4M25520/23-045cLocator, pin/socket 4297-30M22520/23-135dCrimping die, pin/socket 414DA-1/on0M25520/23-055eCrimping die, pin/socket 4297-66M22520/23-105fCrimping die, pin/socket 414DA-6N6M22520/23-03b.RemovalofCableInsulation. When installing electrical connectors to cable ends, cut and remove cablejacket and insulation as follows:.(1)100-amp.8-wirecables.Do not cut insulation on individual wires when cutting cable jacket.(a)Carefully cut and remove 3-1/2 inches (89 mm) of outer cable jacket from end of cable.(b)Carefully cut and remove 7/8 inch (22 mm) of conductor insulation from each conductor.(c)Attach electrical connector to cable end.(2)60-amp.5-wirecables.Do not cut insulation on individual wires when cutting cable jacket.(a)Carefully cut and remove 3-1/2 inches (89 mm) of outer cable jacket from end of cable.(b)Cut off 12 inch (13 mm) from phases A, B, C and neutral conductor (the four large conductors).(c)Carefully cut and remove 7/8 inch (22 mm) of conductor insulation from end of each conductor.(d)Attach electrical connector to cable end.G-2