TM 9-6150-228-13&P
G.2
GENERAL INFORMATION - CONTINUED.
Table G-2. Crimp Tools
Item No.
Nomenclature
Size
Part Numbers
1
Removal Tool, Pin/Socket M81969/27-3
1
MS90562-3
2
Removal tool, pin/socket
4
TP201315-04
3
Removal tool, pin/socket M81969/274
6
MS90562-6
4
Installer tool, pin/socket
4
M81969/17-07
5
Crimp tool system, pneumatic 400-1-200-5KL
-
M25520/23-01
5a
Locator, pin/socket 4297-5
4
M22520/23-12
5b
Crimping die, pin/socket 414DA-4N
4
M25520/23-04
5c
Locator, pin/socket 4297-3
0
M22520/23-13
5d
Crimping die, pin/socket 414DA-1/on
0
M25520/23-05
5e
Crimping die, pin/socket 4297-6
6
M22520/23-10
5f
Crimping die, pin/socket 414DA-6N
6
M22520/23-03
b.
Removal of Cable Insulation. When installing electrical connectors to cable ends, cut and remove cable
jacket and insulation as follows:.
(1)
100-amp. 8-wire cables.
Do not cut insulation on individual wires when cutting cable jacket.
(a)
Carefully cut and remove 3-1/2 inches (89 mm) of outer cable jacket from end of cable.
(b)
Carefully cut and remove 7/8 inch (22 mm) of conductor insulation from each conductor.
(c)
Attach electrical connector to cable end.
(2)
60-amp. 5-wire cables.
Do not cut insulation on individual wires when cutting cable jacket.
(a)
Carefully cut and remove 3-1/2 inches (89 mm) of outer cable jacket from end of cable.
(b)
Cut off 12 inch (13 mm) from phases A, B, C and neutral conductor (the four large conductors).
(c)
Carefully cut and remove 7/8 inch (22 mm) of conductor insulation from end of each conductor.
(d)
Attach electrical connector to cable end.
G-2