TM 9-6150-226-13
NOTES:
1.
2.
3.
4.
THIS FIGURE ILLUSTRATES ASSEMBLY OF THE FOLLOWING:
M200 A/P FEEDER CENTER, CONNECTOR J6
M100 A/P FEEDER CENTER, CONNECTOR J8
ALL DIMENSIONS ARE IN INCHES, WITH METRIC EQUIVALENTS IN PARENTHESES.
REMAINING WIRES ARE REMOVED FOR CLARITY.
CUT AND REMOVE WIRE INSULATION AS INDICATED.
CRIMP ELECTRICAL CONTACT SOCKETS TO WIRES FOR POSITIONS AS FOLLOWS:
M200 A/P, CONNECTOR J6
ITEM
WIRE
WIRE
POSITION
NO.
SIZE
LENGTH
A
4 and 5
12
12 (304.8 MM)
B
4 and 5
12
12 (304.8 MM)
c
4 and 5
12
10 (254.0 MM)
M100 A/P, CONNECTOR J8
ITEM
WIRE
WIRE
POSITION
NO.
SIZE
LENGTH
A
4 and 5
12
14 (355.6 MM)
4 and 5
12
14 (355.6 MM)
C
4 and 5
12
14 (355.6 MM)
6. ELECTRICAL CONNECTOR (ITEM 2) IS FURNISHED WITH THE FOLLOWING:
COVER (ITEM 1)
GASKET (ITEM 3)
ELECTRICAL CONTACT PINS (ITEM 5)
7. ASSEMBLE CONNECTOR SO KEYWAYS AND SOCKETS ALINE AS INDICATED.
FIGURE F-34. PDISE 20-amp output connector assembly. (sheet 2 of 2)
F-91