TM 9-6115-730-24
0009
TROUBLESHOOTING USING GSC FAULT CODES - Continued
NOTE
This fault code means the GSC detected a short to B+ or B- on one of the lines (P7-21 and
P7-22) of the CCM data link. The CCM output is not used.
SYMPTOM
57.
CID 770 FMI 09
MALFUNCTION
Customer Communication Module (CCM) Data Link.
FMI 09 - Abnormal Update.
CORRECTIVE ACTION
STEP 1.
Troubleshoot data link per WP 0013, SYMPTOM 7.
STEP 2.
If the problem is not resolved, replace ECM (WP 0082).
STEP 3.
Verify the problem has been resolved.
0009-48