TM 9-6115-729-24
0031
REMOVAL
1.
Remove seven screws (Figure 1, Item 1), washers (Figure 1, Item 2), and lockwashers (Figure 1, Item 3).
2.
Remove 46 screws (Figure 1, Item 5), lockwashers (Figure 1, Item 6), and washers (Figure 1, Item 7) from
engine compartment ceiling assembly (Figure 1, Item 4) (23 sets on each side).
3.
Remove two screws (Figure 1, Item 8), lockwashers (Figure 1, Item 9), and washers (Figure 1, Item 10)
securing bracket (Figure 1, Item 11) to air cleaner bracket (Figure 1, Item 12).
4.
Remove two screws (Figure 1, Item 13), washers (Figure 1, Item 14), lockwashers (Figure 1, Item 15), nuts
(Figure 1, Item 17) and four clamps (Figure 1, Item 16) with hoses from second and fifth holes from end of
generator set.
5. Remove engine generator compartment ceiling assembly (Figure 1, Item 4).
END OF TASK
DISASSEMBLY
1.
Remove five screws (Figure 1, Item 18), washers (Figure 1, Item 19), lockwashers (Figure 1, Item 20), nuts
(Figure 1, Item 21) and bracket (Figure 1, Item 22).
2.
If necessary, remove 42 clips (Figure 1, Item 23), 21 push-on nuts (Figure 1, Item 24) and remove foam
damping section.
END OF TASK
ASSEMBLY
1. If necessary, use old foam damping section as template to cut new foam damping section. Install foam
damping section, 21 push-on nuts (Figure 1, Item 24), and 42 clips (Figure 1, Item 23).
2. Install bracket (Figure 1, Item 22) using five screws (Figure 1, Item 17), washers (Figure 1, Item 18),
lockwashers (Figure 1, Item 19), and nuts (Figure 1, Item 21). (Note that second and fifth hardware sets from
rear of generator set are left out in order to attach hoses and clamps under the ceiling after it is installed.)
0031-2