ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
Table 5-15. No
Output Voltage (MEP-531A) Troubleshooting
No output voltage
(MEP-531A)
Check for voltage
No Voltage
Voltage
across TB1 connectors
8 and 9
Residual field flash
Test for defective voltage
magnetism may be lost.
Not OK
regulator (A1), refer to
Momentarily apply 9 VDC at
TB1 connectors 8(+) and 9(-)
to restore residual magnetism.
Replace defective
voltage regulator (A1),