ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
2-18
TABLE 2-5. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
(continued)
B-BEFORE
D-DURING
A-AFTER
Interval
Item
No.
B
D
A
Item to
be inspected
Procedures
Check for and have
repaired or adjusted
as necessary
Equipment is
not ready/
available if:
__________
WARNING
Cooling system operates at high
temperature and pressure. Contact
with high pressure steam and/or
liquids can result in burns and
scalding. Shut down generator set,
and allow system to cool before
performing checks, services, and
maintenance. Failure to comply can
cause injury to personnel.
COOLING
SYSTEM
10
Radiator
Check radiator for leaks, damage, or
missing parts.
Class III leaks.
Radiator cap is
missing.
11
Hoses
Check hose for leaks or cracks.
Class III leaks.
12
Cooling Fan
Check fan for damage or looseness.
Cooling fan is
damaged or loose.
Check for unusual noise being emitted
from fan area.
13
Fan Belts
Inspect belts for cracks, fraying, or
looseness.
Broken belt(s).
14
Overflow Bottle
Check overflow bottle for leaks and
missing parts.
Class III leaks.
Check overflow bottle coolant level.
Coolant level is
below COLD line.
EXHAUST/
INTAKE SYSTEM
15
Exhaust System
Check muffler for leaks and exhaust
system for corrosion and damaged or
missing parts.
Muffler or exhaust
system damaged or
leaking excessively.