ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
1-6
TABLE 1-1. TABULATED DATE (Continued)
MEP-806B
MEP-816B
6. Engine Starting System (Continued)
c. Battery Charging Alternator:
(1) Manufacturer
Bosch
Bosch
(2) Model
9 120 060 039
9 120 060 039
(3) Rating
42 amps at 24 VDC
42 amps at 24 VDC
(4) Protective Fuse
30 amps
30 amps
7. AC Generator:
a. Manufacturer
Marathon Electric
Marathon Electric
b. Type
Rotating field, synchronous
Rotating field, synchronous
c. Load Capacity
60 Kw
60 kW
d. Model
88-21009
88-21010
e. Current Ratings:
(1) 120/208 volt connection
60 Hz: 208 amps
208 amps
50 Hz: 173 amps
(2) 240/416 volt connection
60 Hz: 104 amps
104 amps
50 Hz: 86 amps
f.
Power Factor
0.8
0.8
g. Cooling
Fan cooled
Fan cooled
h. Drive Type
Direct coupling
Direct coupling
i.
Duty Classification
Continuous
Continuous
8. Governing System:
a. DCS Load Sharing Synchronizer:
(1) Manufacturer
Governors of America
Governors of America
(2) Model
LSS100
LSS400
b. DCS Speed Control Unit:
(1) Manufacturer
Governors of America
Governors of America
(2) Model
ESD5551
ESD5551
c. I/O Interface Module
(1) Manufacturer
Governors of America
Governors of America
(2) Model
TCM100
TCM400
d. Backplane Module
(1) Manufacturer
Governors of America
Governors of America
(2) Model
TCM102
TCM102
e. Automatic Voltage Regulator
(1) Manufacturer
Governors of America
Governors of America
(2) Model
AVR100
AVR100
1.13.2 DATA PLATES. There are data plates at various locations on the generator set to provide instructions, cautions,
and identification. Figures 1-2 through 1-18 show the location and contents of each plate on the generator set. The
wiring diagram and schematic diagram plates are located at the back of this manual as fold-outs.