ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-91
(6)
Hold FAULT RESET switch (21) in ON position. Multimeter should indicate continuity between
terminals 1 and 2 and an open circuit between terminals 2 and 3.
(7)
If indications are not as above, replace FAULT RESET switch (21).
(8)
Connect electrical leads to FAULT RESET switch (21), and remove tags.
(9)
Raise and secure DCS control panel with two fasteners.
(10) Connect negative battery cable to battery, and close BATTERY ACCESS door.
c. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Release DCS control panel by turning two fasteners, and lower DCS control panel slowly.
(4)
Tag and disconnect electrical leads from FAULT RESET switch (21, Figure 4-12).
(5)
Remove jamnut (19) and toothed washer (20) securing FAULT RESET switch (21) to DCS control
panel.
(6)
Remove FAULT RESET switch (21) and tab washer (22), from DCS control panel.
(7)
Position tab washer (22) and FAULT RESET switch (21) on DCS control panel.
(8)
Secure FAULT RESET switch (21) to DCS control panel with toothed washer (20) and jamnut (19).
(9)
Connect electrical leads to FAULT RESET switch (21), and remove tags.
(10) Raise and secure DCS control panel with two fasteners.
(11) Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.8.9
MASTER CONTROL Switch S3.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Release DCS control panel by turning two fasteners, and lower DCS control panel slowly.
(3)
Inspect MASTER CONTROL switch (3, Figure 4-13) for loose connections and mounting
hardware, and other damage.
(4)
Raise and secure DCS control panel with two fasteners.