ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-12
TABLE 4-4. UNIT TROUBLESHOOTING
Not OK
OK
OK
No
Yes
ENGINE FAILS TO CRANK
Engine fails to
crank.
Check FAULT INDICATOR on
CIM display screen. Is a fault
displayed?
Go to troubleshooting section
corresponding to fault
displayed. See Symptom
Index, page 4-10.
Check for loose or
corroded battery cable
terminals or battery posts.
Inspect batteries
(see para.4.6.3).
Clean and tighten
battery cable terminals
and battery posts.
Replace batteries
(see para.4.6.3).
Continued on
next page.
Not OK