NOTE
Restriction indicator will pop out displaying a red band when flow through the
air cleaner is restricted and requires service.
NOTE
Restriction indicator is located halfway between the left side engine access door
and the rear of the generator set. It may be necessary to use a flashlight to see
the indicator.
(10) Inspect restriction indicator (2). If the red indicator is visible, reset by pressing the reset button
(8).
(11) Close left side engine compartment access doors.
3.3.4
Crankcase Breather Filter Assembly.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
__________
WARNING
Exhaust system can get very hot. Allow system to cool before performing
maintenance. Failure to comply can cause severe burns and injury to
personnel.
(2)
Open right side engine compartment access door (Figure 1-2).
(3)
Inspect sight glass (1, Figure 3-2). If fluid is visible, service crankcase breather filter assembly,
(3) step b below.
(4)
Inspect hoses (2) for cracks, holes, dry rot, and damaged or missing hose clamps.
(5)
Inspect crankcase breather filter assembly (3) for cracks, excessive corrosion, and other damage.
(6)
Close engine compartment access doors.
b. Service.
(1)
Shut down generator set, paragraph 2.11.2.
__________
WARNING
Exhaust system can get very hot. Allow system to cool before performing
maintenance. Failure to comply can cause severe burns and injury to
personnel.
(2)
Open right side engine compartment access doors (Figure 1-2).