ARMY TM 9-6115-671-14
A AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
G-5
NOTES:
1. Dimensions shown are in inches.
2. Refer to TM 9-6115-671-24P for materials required.
PROCEDURES:
1. Cut wire (1) to length indicated.
2. Strip 0.75 inch of insulation from each end of wire (1).
3. Position insulation sleeving (2) on center of wire (1). Mark sleeving with wire number "165B0", and shrink to
fit.
4. Mark insulation sleeving (4) with "POSITIVE", and slide over one end of wire (1).
5. Crimp terminal (3) on each end of wire (1).
6. Position insulation sleeving (4) as shown, and shrink to fit.
Figure G-4. Cable Assembly, Battery (P/N 88-22181)