ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
G-2
G.2
ILLUSTRATIONS.
NOTES:
1. Dimensions shown are in inches.
2. Refer to TM 9-6115-671-24P for materials required and length (L) of wire.
PROCEDURES:
1. Cut wire (1) to length indicated.
2. Strip 0.75 inch of insulation from each end of wire (1).
3. Crimp terminal (2) on each end of wire (1).
Figure G-1. Cable Assembly, AC Power (P/Ns 88-22126-1 through 88-22126-7)