ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-156
c. Installation.
(1)
Install filler neck (2, Figure 4-22), chain (10), bolts (9), and locknuts (8) on radiator fill panel (7).
(2)
Position radiator fill panel (7) and filler neck (2) in generator set.
(3)
Position overflow hose (6) and hose clamp (5) on filler neck (2). Tighten hose clamp.
(4)
Position filler hose (4) and hose clamps (3) on filler neck (2) and radiator. Tighten hose clamps.
(5)
Close coolant drain valve (33), and add coolant/antifreeze to proper level at the filler neck (2).
(6)
Install radiator cap (1) on filler neck (2).
(7)
Install top housing panel. Refer to paragraph 4.7.3.
(8)
Start generator set, paragraph 2.11.1. Allow unit to reach operating temperature, and check for
leaks.
(9)
Add coolant/antifreeze to overflow bottle as required, paragraph 3.3.4.
(10) Close engine compartment access doors.
4.10.3 Fan Guards.
CAUTION
Fan shroud must be installed when operating Generator Set.
a. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Open right side engine compartment access doors (Figure 1-2).
(4)
Remove bolts (1, Figure 4-23), washers (2), lockwashers (3), and right fan guard (5) from brackets
(10, and 11).
(5)
Remove bolt (14), lockwasher (13), washer (12), and bracket (9) from engine.
(6)
Remove bolts (14), lockwashers (13), washers (12), and brackets (10 and 11) from shroud.
(7)
Open left side engine compartment access doors (Figure 1-3).
(8)
Remove bolts (1), washers (2), lockwashers (3), and left fan guard (4) from brackets (6, 7, and 8).
(9)
Remove bolt (14), lockwasher (13), washer (12), and bracket (6) from engine.
(10) Remove bolts (14), lockwashers (13), washers (12), and brackets (7 and 8) from shroud.