ARMY TM 9-6115-670-14&P
6-55
Figure 6-20. Connecting Rod (Sheet 1 of 4)
c. Test connecting rod alignment.
(1)
Install connecting rod cap to connecting rod (para 6.28., REPLACE, step h).
(2)
Refer to Figure 6-20 (sheet 2) and install connecting rod to connecting rod alignment tool.
(3)
Install piston pin (1, Figure 6-20 (sheet 4)) in connecting rod and set gauge on pin (Figure
6-20, sheet 2).
(4)
Refer to Figure 6-20 (sheet 2) and measure the gaps of the three points between the pins
and the flat surface of the alignment tool.
(5)
Gaps should not exceed 0.0020 in. (0.05 mm). If gap exceeds tolerance, replace
connecting rod.