ARMY TM 9-6115-670-14&P
5-76
5.25. WIRING HARNESS REPAIR.
This task covers: Repair
INITIAL SETUP
Tools
General Mechanic's Tool Kit
(Item 1, Appendix B)
Shop Equipment, Electrical Repair,
Semitrailer Mounted
(Item 3, Appendix B)
Pin Remover
(Item 28, Appendix B)
Heater, Gun Type, Electric
(Item 33, Appendix B)
Equipment Conditions
MASTER ON-OFF switch on APU control unit set
to OFF.
Materials/Parts
Wiring Harness, Engine P1
APU DC Box Wiring Harness J3
Wiring Harness J1
Wiring Harness J2
References
Figures FO-1 and FO-2, FO-3, FO-4,
FO-5 or FO-7
REPAIR
a. Crimp-on terminals and lugs.
(1)
Remove terminal or lug by cutting lead at base of terminal or lug.
(2)
Strip no more than 1/4 in. (6.35 cm).
(3)
Using a crimping tool, crimp terminal or lug to lead.
b. Connectors with pins.
(1)
Using pin puller, push pin out through back of connector.
(2)
Cut lead at base of pin.
WARNING
Ensure that APU DC power supply is disconnected.
Failure to observe this warning could result in severe
injury or DEATH to personnel.
WARNING
Ensure that the APU is turned off and completely de-
energized before opening generator housing.
Failure to observe this warning could result in severe
injury or DEATH to personnel.
NOTE
Use this procedure to repair APU wiring harnesses
Engine P-1, J-1, J-2, APU DC Box J-3, and
interconnect control cable.