ARMY TM 9-6115-670-14&P
5-62
REPLACE
a. Remove four screws (JTACS), or slotted hex-head bolts (SICPS and WIN-T), flat and lock
washers (4), and remove generator housing top cover (3).
b. Remove two screws, wing nuts and lock washers (6a) (JTACS), or four slotted hex-head bolts
(SICPS and WIN-T), flat and lock washers (6), and remove generator housing side cover (5)
(muffler side).
c. Refer to foldout FO-1 (SICPS/WIN-T) or F0-7 (JTACS) and tag and disconnect electrical leads
to AVR (1).
d. Remove four nuts with captive washers (2) and AVR (1).
e. Install AVR (1) and secure with four nuts with captive washers (2).
f. Reconnect electrical leads to AVR (1).
g. Install generator housing side cover (5) and secure with two screws, wing nuts and lock
washers (6a) (JTACS), or four slotted hex-head bolts (SICPS and WIN-T), flat and lock
washers (6).
h. Install generator housing top cover (3) and secure with four screws (JTACS), or four slotted
hex-head bolts (SICPS and WIN-T), flat and lock washers (4).
WARNING
Ensure that APU DC power supply is disconnected.
Failure to observe this warning could result in severe
injury or DEATH to personnel
WARNING
Ensure that the APU is turned off and completely de-
energized before opening generator housing.
Failure to observe this warning could result in severe
injury or DEATH to personnel.