f. Remove cannon plug (P1 from J1).
g. Remove four screws (JTACS), slotted hex bolts, and lock washers (SICPS and WIN-T) (5, Figure 5-
17) securing regulator box (2) to generator housing (11).
h. Remove three bolts and lock washers (4) and regulator box (2).
i. Remove two captive screws (1) and flat washers from regulator box (2).
j. Maneuver regulator box to access machine screws (9, Figure 4-43) and nuts with captive washers
(5) securing shunt (6) to box. Remove machine screws (9) and nuts with captive washers (5) and
current shunt (6).
k. Install current shunt (6), two machine screws (9), and nuts with captive washers (5).
l. Install two captive screws (1, Figure 5-17) and flat washers to regulator box.
m. Install three bolts and lock washers (4) and regulator box (2).
n. Install four screws (JTACS), slotted hex bolts, and lock washers (5) (SICPS and WIN-T) securing
regulator box (2) to generator housing (11).
o. Connect cannon plug (P1 to J1).
p. Install two bolts, lock washers and flat washers (5, Figure 4-5) to generator bracket (6) and air
deflector (4).
q. Install electrical leads (8a, Figure 4-43) to shunt and secure with two hex-head bolts and flat
washers (8).
r. Install electrical leads (6a) to shunt and secure with two machine screws (7).
s. Install two screws, two wing nuts and lock washers (4a) (JTACS), or four slotted hex-head bolts
(SICPS and WIN-T), flat and lock washers (4), and generator housing side cover (3).
t. Install generator housing top cover (1) and secure with four screws (JTACS), or slotted hex-head
bolts (SICPS and WIN-T), flat and lock washers (2).
NOTE
Restrain nut from spinning with number 2, 3/16-in. flat-
tipped screwdriver.