ARMY TM 9-6115-670-14&P
4-121
4.48. GOVERNOR CONTROL ASSEMBLY.
This task covers:
a. Test
b. Replace
INITIAL SETUP
Tools
Shop Equipment, Electrical
Repair, Semitrailer Mounted
(Item 3, Appendix B)
Equipment Conditions
MASTER ON-OFF switch on APU control unit
set to off.
Materials/Parts
Multimeter
Governor Control Assembly
Air filter removed (para 4.45.).
TEST
a. Remove top cover (18, Figure 4-36).
b. Tag and remove electrical leads P7 (7, Figure 4-19) from J7 (6).
c. Attach multimeter leads to pins A and B of P7 (7).
d. Start APU (para 2.5.). Check for voltage.
e. After engine speed has stabilized, move control arm on governor to vary engine speed. Multi-meter
should read between 24 and 28 VDC. If multimeter does not read between 24 and 28 VDC,
governor control is faulty. Shut down APU (para 2.6.) and replace governor control assembly.
REPLACE
WARNINGS
Ensure that APU DC power supply is disconnected.
Ensure that the APU is turned off and completely de-
energized before opening generator housing.
Failure to observe these warnings could result in severe
injury or DEATH to personnel.
WARNING
DC voltages are present at generator set components
even with generator set shutdown. Avoid grounding
self when touching any electrical components. Failure
to observe this warning can result in personal injury or
DEATH by electrocution.
NOTE
In order to avoid a low fuel fault shutdown of the
APU, testing time shall not exceed three minutes
maximum.