TABLE 2-5. Unit Preventive Maintenance Checks and Services - Continued
M - Monthly
Q - Quarterly
S - Semi-annually
A - Annually
B - Bi-annually
H - Hours
Interval
Procedures:
Equipment Is
Item
Item to be
Check for and have repaired
Not Ready/
No.
M Q
S
A B
H
Inspected
or adjusted as necessary
Available If:
7
750
Air Cleaner
Remove, clean, and inspect
Tubing and
tubing and breather. Refer
Breather
to paragraph 2-75.
8
300
Hardware and
Inspect for loose, damaged,
Loose, missing,
Sound
or missing hardware and
or damaged
Insulation
sound insulation. Tighten
hardware or
loose hardware. Repair or
insulation.
replace damaged or missing
hardware or insulation.
9
1500
Radiator and
Clean radiator exterior sur-
Interior of
faces. Refer to paragraph
Generator Set
2-82. Clean engine
compartment.
10
1500
Magnetic
Remove, inspect, and clean
Magnetic pick-
Pickup
magnetic pickup. Refer to
up is damaged.
paragraph 2-110.
11
Wiring
Inspect wiring harnesses for
Wiring
Harness
breaks and loose connect-
harnesses are
ions. Repair and tighten
damaged or
wiring harnesses as
connections are
necessary.
loose.
12
3000
Muffler
Check muffler for leaks,
Muffler leaks, is
restriction, and accumula-
restircted, or
tion of carbon. Replace or
has excessive
clean as required
carbon accum-
ulation.
13
300
Governor
Clean and lubricate gov-
Linkage
ernor actuator linkage rod
ends.
NOTE
If the auxiliary fuel system
is used as the primary fuel
source, the auxiliary fuel
filter must be replaced
semi-annually.
14
500
Auxiliary Fuel
Check for proper operation
Filter
using the auxiliary fuel
system as primary source.
15
1500
Fan Belt
Replace fan belt. Refer to
paragraph 2-84-3
2-10 Change 4