ARMY TM 9-6115-645-24
AIR FORCE TO 35C2-3-444-12
MARINE CORPS TM 09244A/09245A-24/2
TABLE 1-1. Tabulated Data - Continued
6. Engine Starting System - Continued:
c. Battery Charging Alternator:
(1) Manufacturer
(2) Model
(3) Rating
(4) Protective Fuse
7. AC Generator:
a. Manufacturer
b. Type
c. Load Capacity
d. Current Ratings:
(1) 120/208 volt connection
(2) 240/416 volt connection
e. Power Factor
f. Cooling
g. Drive Type
h. Duty Classification
8. Governing System:
a. Load Measuring Unit:
(1) Manufacturer
(2) Model
b. Governor Control Unit:
(1) Manufacturer
(2) Model
9. Protection Devices:
a. Low Oil Pressure Switch:
(1) Trip Pressure
(2) Voltage Rating
(3) Current Rating
b. Coolant High Temperature Switch:
(1) Trip Temperature
(2) Voltage Rating
(3) Current Rating
MEP-806A
Prestolite
8EM3002GC
42 amps at 24 VDC
30 amps
Marathon Electric
Rotating field, synchronous
60 KW
60 Hz: 208 amps
50 Hz: 173 amps
60 Hz: 104 amps
50 Hz: 86 amps
0.8
Fan Cooled
Direct Coupling
Continuous
Technology Research
19310
Barber-Colman
DYNA 10502-003-0-2
15 + 3 psi (103.4 ± 20.7 kPa)
24 VDC
7 amps
225 ± 5°F(107 ± 3°C)
24 VDC
7 amps
MEP-813A
Prestolite
8EM3002GC
42 amps at 24 VDC
30 amps
Marathon Electric
Rotating field, synchronous
60 KW
208 amps
104 amps
0.8
Fan Cooled
Direct Coupling
Continuous
Technology Research
19310
Barber-Colman
DYNA 10502-003-0-2
15 ± 3 psi (103.4 ± 20.7 kPa)
24 VDC
7 amps
225 ± 5 °F (107 ± 3°C)
24 VDC
7 amps
1-6