Item
No.
ARMY TM 9-6115-645-10
AIR FORCE TO 35C2-3-444-11
MARINE CORPS TM 09244A/09245A-10/1
TABLE 2-3.
Operator Preventive Maintenance Checks and Services -
Continued
B - BEFORE
D - DURING
A - AFTER
10
11
12
13
Interval
B
Item to
be inspected
COOLING
SYSTEM
Radiator
Hoses
Cooling Fan
Fan Belts
Procedures
Check for and have
repaired or adjusted
as necessary
WARNING
Cooling system
operates at high
temperatures.
Personal injury or
death from burns
or scalding can
result from contact
with high pressure
steam and/or liquid.
Check radiator for
leaks, damage or
missing parts.
Check hoses for
leaks or cracks.
Check fan for damage
or looseness.
Check for unusual
noise being emitted
from fan area.
Inspect belts for
cracks, fraying
and looseness.
Equipment is
not ready/
available if:
Class III
leaks.
Radiator cap
missing.
Class III
leaks.
Cooling fan is
damaged or
loose.
Broken
belt(s).
2-13