TABLE 1-1. Tabulated Data - Continued
MEP-805A
MEP-815A
8. Governing System - Continued:
(1) Manufacturer
Technology
Research
(2) Model
19310
19310
b. Governor Control Unit:
(1) Manufacturer
Barber-Colman
Barber-Colman
(2) Model
DYNA 10502-002-0-2
DYNA 10502-002-0-2
9. Protective Devices:
a. Low Oil Pressure
switch:
(1) Trip Pressure
1 5 ± 3 p s i
1 5 ± 3 p s i
(103.4 ± 20.7 kPa)
(103.4 ± 20.7 kPa)
(2) Voltage Rating
24 VDC
24 VDC
(3) Current Rating
7 amps
7 amps
b. Coolant High
Temperature Switch:
(1) Trip Temperature
225 ± 5° F
225 ± 5° F
(107 ± 3° C)
(107 ± 3° C)
(2) Voltage Rating
24 VDC
24 VDC
(3) Current Rating
7 amps
7 amps
c. Overspeed Switch:
(1)
2200 ± 40 RPM
2200 ± 40 RPM
(2) Voltage Rating
28 VDC
28 VDC
(3) Current Rating
1 amp
1 amp
d. Overvoltage Relay:
(1) Trip Point
153 ± 3 VAC for no
153 ± 3 VAC for no
Conditions
less than 200
less than 200
milliseconds
milliseconds
(120 VAC coil
(120 VAC coil
winding)
winding)
(2) Trip Point
No more than 1.25
No more than 1.25
seconds after trip
seconds after trip
conditions exist
conditions exist
1-8