ARMY TM 9-6116-644-24
AIR FORCE TO 35C2-3-446-12
MARINE CORPS TM 09249A/09246A-24/2
1-6 LEVELS OF MAINTENANCE.
1-6-1
(A) Army users shall refer to the Maintenance Allocation Chart (MAC) for tasks and levels of maintenance to
be performed.
1-6-2
(F) (MC) Refer to the Source Maintenance Recoverability (SMR) Codes for maintenance to be performed.
1-6-3
(N) Navy users shall determine their maintenance levels in accordance with their service directives.
1-7
DESTRUCTION OF MATERIEL TO PREVENT ENEMY USE.
1-7-1
(A) (MC) Destruction of the generator set to prevent enemy use shall be in accordance with TM 750-244-3.
1-7-2
(F) (N) Air Force and Navy users shall refer to their service directives to obtain procedures for destruction of
materiel to prevent enemy use.
S e c t i o n I l . E Q U I P M E N T D E S C R I P T I O N A N D D A T A
1-8 GENERAL.
The generator sets, models MEP-805A and MEP-815A, (FIGURE 1-1) are fully enclosed, self-contained,
skid-mounted, portable units. They are equipped with controls, instruments, and accessories necessary for operation as
single units or in parallel with another unit of the same class and mode. The generator sets consist of a diesel engine,
brushless generator, excitation system, speed governing system, fuel system, 24 VDC starting system, control system,
and fault system.
1-9 TABULATED/ILLUSTRATED DATA.
For a list of Tabulated Data refer to TABLE 1-1.
TABLE 1-1. Tabulated Data
1. Generator Set:
a. National Stock Number
b. Overall Length
c. Overall Width
d. Overall Height
e. Dry Weight (less Basic
Issue Items List)
f. Wet Weight
MEP-805A
MEP-815A
6115-01-274-7389
79.7 in.
(202.5 cm)
35.7 in.
(90.8 cm)
55 in.
(139.7 cm)
2732 lb.
(1239.2 kg)
2931 lb.
(1329.5 kg)
6115-01-274-7394
79.7 in.
(202.5 cm)
35.7 in.
(90.8 cm)
55 in.
(139.7 cm)
2732 lb.
(1239.2 kg)
2931 lb.
(1329.5 kg)
1-4