ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
TABLE 1-1. Tabulated Data - Continued
5. Fuel System - Continued:
d. Auxiliary Fuel Pump:
(1) Voltage Rating
(2) Delivery Pressure
e. Fuel Level Switch:
(1) Type
(2) Current
6. Engine Starting System:
a. Batteries
b. Starter:
(1) Manufacturer
(2) Model
(3) Voltage Rating
(4) Drive Type
c. Battery Charging
Alternator:
(1) Manufacturer
(2) Model
(3) Rating
(4) Protective Fuse
7. AC Generator:
a. Manufacturer
b. Type
c. Load Capacity
d. Current Ratings:
(1) 120/208 volt
connection
(2) 240/416 volt
connection
MEP-804A
24 VDC
5.0-6.5 psi
34.5-65.5 kPa)
Float
0.6 amps (rein) at
24 VDC
Two 12 volt, connected in
series
Hitachi
S25-121
24 VDC
Gear reduction
Hitachi
LR220-24
20 amps at
24 VDC
30 amps
Marathon
Electric
Rotating field,
synchronous
15KW
60 Hz: 52 amps
50 Hz: 43 amps
60 Hz: 26 amps
50 Hz: 21 amps
MEP-814A
24 VDC
5.0-6.5 psi
(34.5-65.5 kPa)
(max)
Float
0.6 amps (min) at
24 VDC
Two 12 volt, connected in
series
Hitachi
S25-121
24 VDC
Gear reduction
Hitachi
LR220-24
20 amps at
24 VDC
30 amps
Marathon
Electric
Rotating field,
synchronous
15 KW
52 amps
26 amps
1-6