ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
Use low pressure air, 15 psi maximum, Wear protective glasses when
using compressed air. Failure to follow this warning could result in se-
vere personal injury.
c. Clean high temperature switch with dry, filtered compressed air and cleaning cloth (Item 7, Appendix C) lightly
moistened with dry cleaning solvent (Item 18, Appendix C).
d. Inspect high temperature switch for cracked casing, corrosion, stripped or damaged threads, and bent or broken
connector pins.
e. If no repair is needed, install coolant high temperature switch, paragraph 2.107.4
2.107.4. Installation.
a. Install coolant high temperature switch (2, FIGURE 2-32) in lower thermostat housing.
b. Connect electrical leads and remove tags.
c. Add coolant to overflow bottle (5, FIGURE 2-26), as necessary, to replace drained coolant
d. Install left side fan guard, paragraph 2.77.3.
e. Close left side engine access door
f. Connect negative battery cable and close battery access door.
2.108. MAGNETIC PICKUP.
2.108.1. Removal
a. Shut down generator set.
b. Open battery access door and disconnect negative battery cable.
c. Open right side engine access door, tag and disconnect magnetic pickup (4, FIGURE 2-31) electrical leads.
d. Loosen lock nut (5) and remove magnetic pickup (4) from flywheel housing. Remove bushing (16).
2.108.2. Cleaning and Inspection.
a. Shut down generator set
b. Remove magnetic pickup, paragraph 2.108.1.
Dry cleaning solvent is flammable and toxic to eyes, skin, and respirato-
ry tract. Skin/eye protection required. Avoid repeated/prolonged con-
tact. Good general ventilation is normally adequate.
Use low pressure air, 15 psi maximum. Wear protective glasses when
using compressed air. Failure to follow this warning could result in se-
vere personal injury.
Change 4
2-153