ARMY TM 9-6115-642-24
AIR FORCE TO 35C2-3-455-12
MARINE CORPS TM 09247A/09248A-24/2
v.
w.
x.
y.
z.
aa.
ab.
ac.
ad.
ae.
af.
ag.
ah.
3-6.2
a.
b.
c.
Using a suitable lifting device or an assistant, lift and rotate rear generator set housing assembly towards left
side and front, clearing skid base.
NOTE
If removing the generator only, proceed to step x.
Disconnect and cap fuel return line at Number 4 injector, refer to TM 9-2815-253-24.
WARNING
Rated capacity of overhead lifting device should be at least 1500 lbs (681 kg).
Damage to the equipment and for severe personal injury or death can occur if a
lifting device with less capacity is used.
NOTE
If removing generator only, attach overhead lifting device to generator lifting point only.
Attach suitable overhead lifting device to lifting points on engine and generator. Take up slack.
NOTE
If removing generator only, proceed to step z.
Remove nuts (1, FIGURE 3-1), washers (2) and (4), and mounting bolts (3) from engine mounting points.
Remove nuts (5), washers (6) and (8), and mounting bolts (7) from generator mounting points.
NOTE
If engine and generator are to be removed as an assembly, perform steps aa and ab.
If removing only the generator, perform steps ac, through af.
Lift engine and generator assembly from skid base and move to appropriate maintenance area.
Remove generator from engine; MEP-803A, refer to paragraph 4-11.1; MEP-813A, refer to paragraph 4-12.1.
Loosen nuts (1) at engine mounting points.
Raise generator approximately 1 in. (2.54 cm) from generator mounting points.
Support rear of engine with wooden shims.
Remove generator from engine; MEP-803A, refer to paragraph 4-11.1; MEP-813A, refer to paragraph 4-12.1.
Remove generator snubbing washers (9, FIGURE 3-1) and shock mounts (10).
Remove snubbing washers (11), nuts (12), lockwashers (13), washers (14) and (16), bolts (15), and engine
shock mounts (17).
Install engine shock mounts (17, FIGURE 3-1) with snubbing washers (11), nuts (12), lockwashers (13), wash-
ers (14) and (16), and bolts (15).
Install generator shock mounts (10) and snubbing washers (9).
WARNING
Rated capacity of overhead lifting device should be at least 1500 lbs (681 kg).
Damage to the equipment and/or severe personal injury or death can occur if a
lifting device with less capacity is used.
Install generator to engine; MEP-803A, refer to paragraph 4-11.4; MEP-813A, refer to paragraph 4-12.6.
NOTE
If only the generator was removed, attach overhead lifting device to generator lift points only.
3-10
Installation.