2-85.4 Installation.
a. Install fittings (7 and 8, FIGURE 2-22) in fuel transfer pump (6).
b. Install fuel transfer pump (6) with bolts (3), Iockwashers (4), and washers (5).
c. Remove caps and connect fuel hose (1) and fuel tube (2) at fuel transfer pump (6).
d. Connect electrical connector and remove tag.
e. Install Ieft side fan guard (4, FIGURE 2-20) with washers (3) and bolts (2).
f.
Connect negative battery cable and close access door.
2-86 FUEL FILTER/WATER SEPARATOR ASSEMBLY.
2-86.1
a.
b.
c.
d.
2-86.2
a.
b.
c.
d.
e.
f.
g.
h.
2-86.3
Shut down generator set.
Open left side engine access door and disconnect negative battery cable.
Inspect fuel filter/water separator assembly for fuel leaks and loose connections.
Connect negative battery cable and dose left side engine access door.
Removal.
Shut down generator set.
Open left side engine access door and disconnect negative battery cable.
Remove control box assembly, paragraph 2-21.2.
Loosen output box mounting hardware to allow access to fuel filter/water separator fuel lines.
Disconnect fuel outlet line (9, FIGURE 2-22), inlet line (2), and water drain line (10) from fuel filter/water sepa-
rator assembly. Cap all lines.
Remove bolts (11), washers (12), nuts (13), Iockwashers (14), and fuel filter/water separator assembly from
generator set.
Remove fuel filter/water separator element, paragraph 2-87.1.
Remove fittings (17) and (18) from base (15).
Repair.
Repair assembly by replacing fuel filter/water separator element.
2-86.4
a.
b.
c.
d.
e.
f.
g.
Install fittings (17 and 18, FIGURE 2-22) in base (15).
Install fuel filter/water separator element, paragraph 2-87.3.
Install fuel filter/water separator assembly in generator set with bolts (11), washers (12), Iockwashers (14),
and nuts (13).
Remove caps and connect water drain line (10), fuel outlet line (9), and fuel inlet line (2) to fuel filter/water
separator assembly.
Tighten output box mounting hardware.
Install control box assembly, paragraph 2-21.4.
Connect negative battery cable and dose access door.
2-113
Inspection.
Installation.