ARMY TM 9-6115-642-24
AIR FORCE TO 35C2-3-455-12
MARINE CORPS TM 09247A/09248A-24/2
2-79.2
a.
b.
c.
d.
e.
2-79.3
a.
b.
c.
d.
Removal.
Shut down generator set.
Open left side engine access door and disconnect negative battery cable.
Remove front housing panel, paragraph 2-18.1.
Tag and disconnect electrical connector from fuel float module (20, FIGURE 2-21).
Remove bolts (18), nuts (19), and fuel float module (20) from generator set.
lnstallation.
Install fuel float module (20, FIGURE 2-21) in generator set with bolts (18) and nuts (19).
Connect electrical connector and remove tag.
Install front housing panel, paragraph 2-18.4.
Connect negative battery cable and close access door.
2-80.1
a.
b.
c.
d.
2-80.2
a.
b.
c.
d.
e.
2-80.3
a.
b.
c.
d.
e.
Inspection.
Shut down generator set.
Remove front housing panel, paragraph 2-18.1.
Inspect fuel lines for deterioration, cracks, and leaks.
Install front housing panel, paragraph 2-18.4.
Removal.
Shut down generator set.
Open left side engine access door and disconnect negative battery cable.
Identify fuel line to be removed as shown in FIGURE 2-21 or FIGURE 2-22.
Disconnect fittings at both ends of fuel line and remove any clamps. Cap openings.
Remove fuel line from generator set.
Remove any caps and position fuel line in generator set.
Install any clamps as removed and connect fittings at both ends of fuel line.
Connect negative battery cable.
Turn MASTER SWITCH to PRIME & RUN or PRIME & RUN AUX FUEL position as applicable, and check for
fuel leaks.
Close all access doors.
2-107
2-80 LOW PRESSURE FUEL LINES.
Installation.