ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
4-54. GOVERNOR ACTUATOR MAINTENANCE - cont.
D. INSPECTION.
1.
Inspect governor actuator for obvious damage. Inspect for corrosion and evidence of electrical short.
Inspect linkage components for obvious damage or defects.
2.
Inspect electrical wiring for cuts, crimps, bare wire, or other damage. Ensure connector plug is securely
attached.
3. Remove and replace any component that is damaged to the extent that it will effect the safe operation of
the generator set.
E. ASSEMBLY.
1.
Install nuts (23, 26, 27, Figure 4-51), spherical washer (24), and ball joint (3) onto linkage rod (22). Attach
link bracket (25) to engine.
2.
Install screw (18), plate (19), washer (20), and nut (21) onto lever (17).
3.
Mate levers (4) to governor actuator (2). Secure by tightening screw (14), washer (15), and nut (16).
4.
Mate lever (17) to lever (4). Secure using screw (11), washer (12), and nut (13).
F. INSTALLATION.
1.
Install governor actuator (2, Figure 4-51) using two screws (8), lockwashers (9), and washers (10).
2.
Adjust actuator / governor linkage as required in accordance with step A, ADJUSTMENT.
3. Connect ball joint (3) on engine linkage with lever (4) using screw (5), washer (6), and locknut (7). Ensure
that the linkage and actuator lever are in the same plane (vertical when viewed from control box end of
generator set).
4. Connect electrical plug (1) to actuator (2).
5. Close main access cover and lock in place using latches.
4-138
Change 1