Remove and discard gasket (71).
e.
Note
Refer to TM 55-1520-214-35 for complete maintenance
of the dc starter-generator.
7-35.
Installation of starter-generator (68) is the reverse of removal.
a.
Apply a light film of petrolatum, Federal Specification VV-P-236, to both sides
b.
of new gasket (71), and to the flange on the output pad of the speed increaser.
Tighten attaching nuts (69) evenly in a criss-cross pattern.
c.
Reconnect the electrical cables to the dc starter-generator.
d.
and 6-3 for the electrical connections.
7-36.
OIL SEALS.
REMOVAL OF OIL SEALS.
7-37.
Remove the ac generator from the output pad of the speed increaser.
a.
Refer to
Remove the dc starter-generator from the output pad of the speed increaser,
b.
See figure 5-1. Remove cover assembly (76) by removing nuts (77) and washers
c.
(78). Reinstall the nuts and washers on the cover to prevent loss.
CAUTION
When removing the oil seals, be careful not to nick the
drive shaft surfaces or the sealing surfaces on the
bearing bore. If these surfaces are nicked, an oil leak
may result.
d.
See figure 5-7. Using a machinist scribe, or equivalent tool, insert the scribe
between the metal part of seal (2) and the rubber part; then pry the seal loose,
and forward.
7-12