TM 5611563214&P
Table 32. Operator/Crew Preventive Maintenance Checks and Services (PMCS) - Cont.
Item
No.
1
2
B
Interval
D A W
Item to be Inspected.
Procedure: check for and
have repaired, filled, or
adjusted as needed
NOTE
Perform weekly as well as before PMCS if
you are operating the equipment for the first
time.
GENERATOR SET EXTERIOR
NOTE
Slight fuel leak (Class I or II leaks) by the
control unit shaft is normal and is necessary
to lubricate shaft. Any other fuel leak or
fuel leakage around the control unit shaft is
a Class III leak and makes the equipment
not ready/available.
a. Check on, around, and beneath the
generator set (1) for fuel or oil leaks.
b. Check that generator set (1) grounds are
properly installed, and grounding
connections are tight.
FUEL GAGE
Check fuel gage (2) for sufficient fuel for
continuous operation.
b Before
D During
A After
W Weeklv
M Monthly
M
Change 3
3-5
Equipment is Not Ready/
Available If
A Class III lubrication oil or
any class fuel leak is detected.
Not properly grounded.