TM 5-6115-631-14&P
Table 3-2. Operator/Crew Preventive Maintenance Checks and Services(PMCS) CONT.
B Before
D During
A After
W - Weekly
M Monthly
Item
no.
1
2
B
l
l
Interval
D
A
W
M
Item to be inspected.
Procedure: check for and
have repaired, filled, or
adjusted as needed
NOTE
Perform weekly as well
PMCS if:
as before
You are the assigned operator but
have not operated the equipment
since the last weekly inspection.
You are operating the equipment
for the first time.
Generator set checks and ser-
vices in this table are described as
performed on a single generator
set. These procedures must be
performed on each of the two
generator sets that make up the
AN/MJQ-16.
GENERATOR SET EXTERIOR
a. Check on, around, and beneath the
generator set (1) for fuel or oil
leaks.
b. Check that generator set (1)
grounds are properly installed,
and grounding connections are
tight.
FUEL GAGE
Check fuel gage (2) for sufficient fuel for
continuous operation.
Equipment is not
ready/available if:
A Class Ill lubrication
oil or any class fuel
leak is detected.
Not properly
grounded.
3-5