TB 9-6115-644-13
Table 2-1. Operator Preventive Maintenance Checks and Services.
Item
Interval
Location
Procedure
Not Fully Mission
No.
Item to Check/Service
Capable if:
NOTE
Refer Generator
TM 9-6115-644-24.
1
Before
VISUAL INSPECTION
Heater assembly
a. Check for damage.
Damage that renders
equipment unsafe.
Heater control unit
b. Check on, around and under
Class III coolant or any
Fuel and coolant lines
equipment for fuel, oil or
class fuel leak is
coolant leaks.
detected.
Check for sufficient fuel supply.
Generator is low on
2
Before
fuel.
3
Before
GENERATOR COOLING
WARNING
SYSTEM
Generator is low on
coolant.
operates at high temperatures.
Personal injury or death from
burns or scalding can result
from contact with high-
pressure steam and/or liquid.
Inspect for loose, damaged or missing
Class III leaks or
RADIATOR
parts.
missing radiator cap.
Inspect for leaks, cracks or missing parts.
Class III leaks or
HOSES
missing clamps or
hoses.
Inspect wiring for burned or frayed
Wiring is loose or
4
Before
HEATER WIRING
insulation or loose terminals.
burned.
CONNECTIONS
Check that indicator light is on when
5
During
HEATER CONTROL
heater is operating. Check Heater
SWITCH AND LIGHT
Function Codes Plate.
Repeat procedures for items 1 - 5.
6
After
ITEMS 1 - 5