TB 9-6115-641-13
1-12
TABULATED/ILLUSTRATED DATA.
1-12.1
Tabulated Data for the heater is located in Table 1-2.
Item Name
Data
1. Winterization Kit
a. National Stock Number
b. Overall Length
10.787 inches
c. Overall Width
5.984 inches
d. Overall Height
7.815 inches
e. Weight
15 lbs
2. Heater:
a. Manufacturer
Active Gear
b. Model
D5W
Water Coolant
Capacity
High: 17,000 BTU/Hr.
Low: 4250 BTU/Hr.
4.
Rated Voltage
24 Vdc
a. Operating Voltage Range
20 to 28 Vdc
b. Current at 24 Vdc
Start: 20 Amps/Hr.
Running High: 1.8 Amps/Hr.
Running Low: 1.2 Amps/Hr.
5. Fuel
Diesel
Fuel Consumption
High: 0.06 Gal/Hr.
Low: 0.04 Gal/Hr.
6.
Coolant Pump Flow
250 Gal/Hr.