TM 9-6150-226-13
NOTES :
1.
THIS FIGURE ILLUSTRATES ASSEMBLY OF THE FOLLOWING:
M200 A/P FEEDER CENTER, CONNECTORS J7 THRU J1O
M1OO A/P FEEDER CENTER, CONNECTORS J3 THRU J6
M40 A/P DISTRIBUTION CENTER, CONNECTOR J2
2.
ALL DIMENSIONS ARE IN INCHES, WITH METRIC EQUIVALENTS IN PARENTHESES.
3.
REMAINING WIRES ARE REMOVED FOR CLARITY.
4.
CUT AND REMOVE WIRE INSULATION AS INDICATED.
5.
CRIMP ELECTRICAL CONTACT SOCKETS TO WIRES FOR POSITIONS AS FOLLOWS:
M200 A/P, CONNECTOR J7 AND J9
ITEM
WIRE
WIRE
POSITION
NO.
SIZE
LENGTH
A
4 and 5
4
23 (584.2 MM)
B
4 and 5
4
23 (584.2 MM)
c
4 and 5
4
23 (584.2 MM)
N
4 and 5
4
12 (304.8 MM)
G
6, 7, and 8
6
18 (457.2 MM)
M200 A/P, CONNECTOR J8 AND J1O
ITEM
WIRE
WIRE
POSITION
NO.
SIZE
LENGTH
A
4 and 5
4
15 (381.0 MM)
B
4 and 5
4
15 (381.0 MM)
C
4 and 5
4
15 (381.0 MM)
N
5 and 8
4
12 (304.8 MM)
G
6, 7, and 9
6
15 (381.0 MM)
F-81