TM 9-6150-226-13
NOTES :
1.
THIS FIGURE ILLUSTRATES ASSEMBLY OF THE FOLLOWING:
M200 FEEDER CENTER, CONNECTORS J4, J5, AND J11
M1OO FEEDER CENTER, CONNECTOR J2
2.
ALL DIMENSIONS ARE IN INCHES, WITH METRIC EQUIVALENTS IN PARENTHESES.
3.
REMAINING WIRES ARE REMOVED FOR CLARITY.
4.
CUT AND REMOVE WIRE INSULATION AS INDICATED.
5.
CRIMP ELECTRICAL CONTACT PINS TO WIRES FOR POSITIONS AS FOLLOWS:
ITEM
WIRE
WIRE
POSITION
NO.
SIZE
LENGTH
A
B
C
N
G1
G2
G3
G4
4 and 6
4 and 6
4 and 6
5 and 6
7, 8, and 9
7, 8, and 9
7, 8, and 9
7, 8, and 9
1
1
1
1
8
8
8
8
14 (355.6 MM)
14 (355.6 MM)
14 (355.6 MM)
14 (355.6 MM)
14 (355.6 MM)
14 (355.6 MM)
14 (355.6 MM)
14 (355.6 MM)
6.
ELECTRICAL CONNECTOR (ITEM 2) IS FURNISHED WITH THE FOLLOWING:
COVER (ITEM 1)
GASKET (ITEM 3)
ELECTRICAL CONTACT SOCKETS (ITEMS 4, AND 7)
7.
ASSEMBLE CONNECTOR SO KEYS AND SOCKETS ALINE AS INDICATED.
FIGURE F-7.
100-amp output connector assembly. (sheet 2 of 2)
F-23