TM 9-6150-226-13
NOTES:
1. ALL DIMENSIONS ARE IN INCHES, WITH THE METRIC EQUIVALENT IN PARENTHESES.
2. CUT AND REMOVE CABLE AND WIRE INSULATION FROM CABLE ENDS AS INDICATED.
3. INSTALL P1 AND P2 CONNECTORS ON PROPER CABLE ENDS SO COLORS AND PINS/SOCKETS
MATCH AS FOLLOWS:
4.
5.
6.
COLOR
FROM
TO
BLACK
P1A
P2-A
WHITE
P1-B
P2-B
GREEN
P1C
P2-C
VERIFY ELECTRICAL CONTINUITY FOR EACH FROM-TO PATH WITH AN OHMMETER.
CRIMP PINS/SOCKETS TO CABLE WIRES.
ASSEMBLE P1 AND P2 CONNECTORS SO KEYS/KEYWAYS AND PINS/SOCKETS ALINE AS
INDICATED.
7. MARK SLEEVES IN ACCORDANCE WITH MIL-M-60903 AS FOLLOWS:
97403-13226E70324
120 VAC
20 AMP
FIGURE F-4. 20-amp, 3.5-ft (1.07m) extension cable. (sheet 3 of 3)
F-17