1-1. SCOPE Section II. EQUIPMENT DESCRIPTION - TM-9-6150-226-13_19Location and Description of Major Components FIGURE 1-1. Typical Field PlacementFIGURE 1-2. DISE and PDISE Branch Cable and Light Assemblies.FIGURE 1-3. Electrical Feeder System, M200 and M200 A/P, 3-PhaseFIGURE 1-4. Electrical Feeder System, M1OO and M1OO A/P, 3-Phase. FIGURE 1-5. Electrical Distribution System, M40 and M40 A/P, 3-Phase. (sheet 1 of 2)FIGURE 1-5. Electrical Distribution System, M40 and M40 A/P, 3-Phase (sheet 2 of 2)FIGURE 1-6. Electrical Distribution System, M60 and M60 A/P Single-Phase. (sheet 1 of 2)FIGURE 1-6. Electrical Distribution System, M60 and M60 A/P Single-Phase. (sheet 2 of 2)FIGURE 1-7. Electrical Utility Kit, M46. (sheet 1 of 2)FIGURE 1-7. Electrical Utility Kit, M46. (sheet 2 of 2)1-12. DIFFERENCE BETWEEN MODELS1-13. EQUIPMENT DATA.Table 1-1. DISE AND PDISE FEEDER/DISTRIBUTION CENTERSTable 1-2. DISE AND PDISE CABLESTable 1-3. APPROXIMATE* VOLTAGE LOSSES AT RATED CURRENTb. Three-Phase Input Systems(3) M40 and M40 A/PTable 1-4. Examples for Pairing Generators with DISE and PDISEFIGURE 1-8. An Example of One Possible Network ArrangementSection III. TECHNICAL PRINCIPLES OF OPERATIONCHAPTER 2 OPERATING INSTRUCTIONS - TM-9-6150-226-13_41Section I. DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS2-2. M1OO DISE FEEDER CENTER AND M1OO A/P PDISE FEEDER CENTERFIGURE 2-1. M200 System Control Panel. (sheet 1 of 3)FIGURE 2-1. M200 System Control Panel. (sheet 2 of 3)FIGURE 2-1. M200 System Control Panel. (sheet 3 of 3)FIGURE 2-2. M200 A/P System Control PanelFIGURE 2-3. M1OO System Control Panel. (sheet 1 of 2)FIGURE 2-3. M100 System Control Panel. (sheet 2 of 2)FIGURE 2-4. M1OO A/P System Control Panel2-3. M40 DISE DISTRIBUTION CENTER AND M40 A/P PDISE DISTRIBUTION CENTER.2-4. M60 DISE DISTRIBUTION CENTER AND M60 A/P PDISE DISTRIBUTION CENTER.FIGURE 2-5. M40 System Control Panel. (sheet 1 of 2)FIGURE 2-5. M40 System Control Panel. (sheet 2 of 2)FIGURE 2-6. M40 A/P System Control Panel FIGURE 2-7. M60 System Control Panel. (sheet 1 of 2)FIGURE 2-7. M 6 0 S y s t e m C o n t r o l P a n e l . ( s h e e t 2 o f 2) FIGURE 2-8. M60 A/P System Control Panel.Section Il. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES2-6. PMCS PROCEDURESTable 2-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICESOPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (Cent) - TM-9-6150-226-13_62OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (Cent) - TM-9-6150-226-13_63OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (Cent) - TM-9-6150-226-13_64OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (Cent) - TM-9-6150-226-13_65OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (Cent) - TM-9-6150-226-13_66Section III. OPERATION UNDER USUAL CONDITIONS - TM-9-6150-226-13_67b. Determining the Users NeedsTable 2-2. RULE OF THUMB FORMULASc. Generator Selection.Table 2-3. EXAMPLE OF DETERMINING USER NEEDSe. DISE and PDISE SelectionTable 2-4. EXAMPLE OF LOAD ASSIGNMENTS FOR THREE/SINGLE-PHASE OUTPUT CONNECTORS OF THE M40 OR M40 A/PTable 2-5. CONNECTOR TO PHASE LINKS - DISE AND PDISE g. Cable Selection. FIGURE 2-9. Typical layout diagram DISE/PDISE.j. Connection to Generator Set.k. Universal AdapterFIGURE 2-10. Universal AdapterI. Circuit Cable LoadsTable 2-6. FEEDER/DISTRIBUTION CENTER OUTPUT CONNECTOR LOADS2-8. OPERATING PROCEDURES2-9. OPERATION OF AUXILIARY EQUIPMENT.b. Auxiliary Equipment2-10. PREPARATION FOR MOVEMENT2-11. OPERATING INSTRUCTIONS ON DECALS AND INSTRUCTION PLATES.FIGURE 2-11. Ground fault test record, right side of control panel.FIGURE 2-12. M200 and M200 A/P data right view. (sheet 1 of 2)FIGURE 2-12. M200 and M200 A/P data plates, left view. (sheet 2 of 2)FIGURE 2-13. M100 and M100 A/P data plates, right view. (sheet 1 of 2)FIGURE 2-13. M100 and M100 A/P data plates, left view. (sheet 2 of 2) FIGURE 2-14. M40 and M40 A/P data plates, right view. (sheet 1 of 2)FIGURE 2-14. M40 and M40 A/P data plates, left view. (sheet 2 of 2)FIGURE 2-15. M60 and M60 A/P data plates, right view. (sheet 1 of 2)FIGURE 2-15. M60 and M60 A/P data plates, left view. (sheet 2 of 2)FIGURE 2-16. Warning tag (located on both ends of DISE and PDISE 3-phase cables)Section IV. OPERATIONS UNDER UNUSUAL CONDITIONS2-12. OPERATION IN EXTREME COLD (Below OF [-18C])2-15. OPERATION IN SALTWATER AREAS2-18. NUCLEAR, BIOLOGICAL, AND CHEMICAL (NBC) DECONTAMINATION PROCEDURES(1) If exposure to liquid agent is known or suspectedCHAPTER 3 OPERATING MAINTENANCE INSTRUCTIONS3-2. TROUBLESHOOTINGTable 3-1. OPERATOR TROUBLESHOOTINGOPERATOR TROUBLESHOOTING (cont)3-3. INTRODUCTIONCHAPTER 4 UNIT MAINTENANCE INSTRUCTIONSSection I. REPAIR PARTS; SPECIAL TOOLS; TEST, MEASUREMENT, AND DIAGNOSTIC EQUIPMENT (TMDE); AND SUPPORT EQUIPMENTSection II. SERVICE UPON Section Index Subject Checking Unpacked Equipment Service Upon Receipt of Materiel 4-5. SERVICE UPON RECEIPT OF MATERIEL. RECEIPT4-6. CHECKING UNPACKED EQUIPMENT.4-8. PMCS INSTRUCTIONSTable 4-2. UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICESUNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES - (Cont.)4-10. TROUBLESHOOTING.SYMPTOM INDEX - TM-9-6150-226-13_116Table 4-3. UNIT TROUBLESHOOTINGUNIT TROUBLESHOOTING (cont) - TM-9-6150-226-13_118UNIT TROUBLESHOOTING (cont) - TM-9-6150-226-13_119T a b l e 4 - 4. DISE AND PDISE FEEDER/DISTRIBUTION CENTER CONTINUITY CHECKSDISE AND PDISE FEEDER/DISTRIBUTION CENTER CONTINUITY CHECKS (cont) - TM-9-6150-226-13_121DISE AND PDISE FEEDER/DISTRIBUTION CENTER CONTINUITY CHECKS (cont) - TM-9-6150-226-13_122DISE AND PDISE FEEDER/DISTRIBUTION CENTER CONTINUITY CHECKS (cont) - TM-9-6150-226-13_123DISE AND PDISE FEEDER/DISTRIBUTION CENTER CONTINUITY CHECKS (cont) - TM-9-6150-226-13_124DISE AND PDISE FEEDER/DISTRIBUTION CENTER CONTINUITY CHECKS (cont) - TM-9-6150-226-13_125DISE AND PDISE FEEDER/DISTRIBUTION CENTER CONTINUITY CHECKS (cont) - TM-9-6150-226-13_126Table 4-6. INCANDESCENT UTILITY LIGHTTable 4-8. DISE AND POISE CABLE CONTINUITY CHECKSDISE AND PDISE CABLE CONTINUITY CHECKS (cont) - TM-9-6150-226-13_129DISE AND PDISE CABLE CONTINUITY CHECKS (cont) - TM-9-6150-226-13_130FIGURE 4-1. M200 Feeder Center Wiring Diagram. (Sheet 1 of 2)FIGURE 4-1. M200 Feeder Center Wiring Diagram. (Sheet 2 of 2)FIGURE 4-2. M100 Feeder Center Wiring DiagramFIGURE 4-3. M40 Distribution Center Wiring DiagramFIGURE 4-4. M60 Distribution Center Wiring DiagramFIGURE 4-5. M200 A/P Feeder Center Wiring Diagram.FIGURE 4-6. M100 A/P Feeder Center Wiring DiagramFIGURE 4-7. M40 A/P Distribution Center Wiring DiagramFIGURE 4-8. M60 A/P Distribution Center Wiring Diagram.FIGURE 4-9. Duplex Receptacle Wiring Diagram.FIGURE 4-10. Incandescent Utility Light Wiring Diagram.FIGURE 4-11. Universal Adapter Wiring DiagramSection V. UNIT MAINTENANCE PROCEDURE4-13. PAINTING.MAINTENANCE OF FEEDER/DISTRIBUTION CENTER ENCLOSURE ASSEMBLIES 4-14 LANYARD, PANEL BOARD, AND CIRCUIT BREAKERS. (cont)TEST - TM-9-6150-226-13_1472. INSTALL CIRCUIT BREAKER. 3. PERFORM CONTINUITY TEST.4-15 CONNECTOR ASSEMBLY - DISE and PDISE.TEST - TM-9-6150-226-13_1514-16 PHASE INDICATOR LIGHT ASSEMBLY AND BULB.2. REMOVE PHASE INDICATOR LIGHT ASSEMBLY.FOLLOW-ON MAINTENANCE4-17 CIRCUIT BREAKER ASSEMBLY AND BUS BAR. 2. REMOVE BUS BAR.3. INSTALL BUS BAR.4. INSTALL CIRCUIT BREAKER ASSEMBLYTEST - TM-9-6150-226-13_1594-18 GASKETMAINTENANCE OF RECEPTACLE GROUPTEST - TM-9-6150-226-13_162MAINTENANCE OF DUAL BULB INCANDESCENT UTILITY LIGHT 3. REMOVE HOOK ASSEMBLYTEST - TM-9-6150-226-13_165MAINTENANCE OF UNIVERSAL ADAPTER2. INSTALL CONNECTOR4-22 DUST AND MOISTURE SLEEVE.b. Secure sleeve plate 4-23 LOAD TERMINAL.FOLLOW-ON MAINTENANCEMAINTENANCE OF CABLE ASSEMBLIESMAINTENANCE OF ROPE ASSEMBLIESMAINTENANCE OF FLUORESCENT LIGHTSection VI. Preparation for Storage or Shipmente. Packaginq.CHAPTER 5 DIRECT SUPPORT MAINTENANCE INSTRUCTIONS - TM-9-6150-226-13_177Section II. DIRECT SUPPORT TROUBLESHOOTINGTable 5-1. DIRECT SUPPORT TROUBLESHOOTINGSection III. DIRECT SUPPORT MAINTENANCE PROCEDURES5-9. MAINTENANCE PROCEDURESb. Keyway and Pin PositionsFIGURE 5-1. 100- and 200-amp, 8-wire connector facesFIGURE 5-2. 40/60-amp, 5-wire connector faces.FIGURE 5-3. 60-amp, 4-wire connector facesFIGURE 5-4. 20-amp, 3-wire connector facesTable 5-2. CRIMP TOOL SELECTION CHARTTable 5-3. CRIMP TOOLS CRIMP TOOLS (cont)Table 5-4. FEEDER/DISTRIBUTION CENTER CONNECTOR REPAIR/FABRICATION REFERENCEFEEDER/DISTRIBUTION CENTER CONNECTOR REPAIR/FABRICATION REFERENCE (cont) - TM-9-6150-226-13_191FEEDER/DISTRIBUTION CENTER CONNECTOR REPAIR/FABRICATION REFERENCE (cont) - TM-9-6150-226-13_192MAINTENANCE OF CABLES1. DISASSEMBLE CONNECTOR5-10 CABLE CONNECTOR. (cont)2. REMOVE CONNECTOR PARTS3. INSTALL CONNECTOR PARTS4. ASSEMBLE CONNECTORb. Slide connector body CABLE CONNECTOR. (cont)MAINTENANCE OF CENTER CONNECTORS1. DISASSEMBLE THE CONNECTORd. Install nut MAINTENANCE OF FEEDER/DISTRIBUTION CENTERS AND UNIVERSAL ADAPTER5-13 ENCLOSURE ASSEMBLY.APPENDIX A REFERENCES - TM-9-6150-226-13_206APPENDIX B MAINTENANCE ALLOCATION CHARTB-3 . EXPLANATION OF COLUMNS IN THE MAC, B-4. COLUMN ENTRIES USED IN TOOL AND TEST EQUIPMENT REQUIREMENTSSection II. MAINTENANCE ALLOCATION CHART FOR DISE/PDISE EQUIPMENTMAINTENANCE ALLOCATION CHART FOR DISE/PDISE EQUIPMENT -cont - TM-9-6150-226-13_211MAINTENANCE ALLOCATION CHART FOR DISE/PDISE EQUIPMENT -cont - TM-9-6150-226-13_212MAINTENANCE ALLOCATION CHART FOR DISE/PDISE EQUIPMENT -cont - TM-9-6150-226-13_213MAINTENANCE ALLOCATION CHART FOR DISE/PDISE EQUIPMENT -cont - TM-9-6150-226-13_214Section III. TOOL AND TEST EQUiPMENT REQUIREMENTS Section iV. REMARKSAPPENDIX C COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS LISTSd. Column (4), Unit of Measure (U/M)Section Il. COMPONENTS OF END ITEMCOMPONENTS OF END ITEM (CONT) - TM-9-6150-226-13_220COMPONENTS OF END ITEM (CONT) - TM-9-6150-226-13_221COMPONENTS OF END ITEM (CONT) - TM-9-6150-226-13_222COMPONENTS OF END ITEM (CONT) - TM-9-6150-226-13_223COMPONENTS OF END ITEM (CONT) - TM-9-6150-226-13_224Section III. BASIC ISSUE ITEMSAPPENDIX E EXPENDABLE/DURABLE SUPPLIES AND MATERIALS LISTSection Il. EXPENDABLE/DURABLE SUPPLIES AND MATERIALS LISTAPPENDIX F ILLUSTRATED LIST OF MANUFACTURED ITEMSDESCRIPTION - TM-9-6150-226-13_230DESCRIPTION - TM-9-6150-226-13_231DESCRIPTION - TM-9-6150-226-13_232DESCRIPTION - TM-9-6150-226-13_233FIGURE F-1. F-6 40/60-amp, 25-ft (7.6m) service/feeder cable. (sheet 1 of 3)FIGURE F-1. 40/60-amp, 25-ft (7.6m) service/feeder cable. (sheet 2 of 3)FIGURE F-1. 40/60-amp, 25-ft (7.6m) service/feeder cable. (sheet 3 of 3)FIGURE F-2. 40/60-amp, 100-ft (30.5m) service/feeder cable. (sheet 1 of 3)FIGURE F-2. 40/60-amp, 100-ft (30.5m) service/feeder cable. (sheet 2 of 3)FIGURE F-2. 40/60-amp, 100-ft (30.5m) service/feeder cable. (sheet 3 of 3)FIGURE F-3. 60-amp, 50-ft (15.2m) service/feeder cable. (sheet 1 of 3)FIGURE F-3. 60-amp, 50-ft (15.2m) service/feeder cable. (sheet 2 of 3)FIGURE F-3. 60-amp, 50-ft (15.2m) service/feeder cable. (sheet 3 of 3)FIGURE F-4. 20-amp, 3.5-ft (1.07m) extension cable. (sheet 1 of 3)FIGURE F-4. 20-amp, 3.5-ft (1.07m) extension cable. (sheet 2 of 3)FIGURE F-4. 20-amp, 3.5-ft (1.07m) extension cable. (sheet 3 of 3)FIGURE F-5. 200-amp input connector assembly. (sheet 1 of 2)FIGURE F-5. 200-amp input connector assembly. (sheet 2 of 2)FIGURE F-6. 100-amp input connector assembly. (sheet 1 of 2)FIGURE F-6. 100-amp input connector assembly. (sheet 2 of 2)FIGURE F-7. 100-amp output connector assembly. (sheet 1 of 2)FIGURE F-7. 100-amp output connector assembly. (sheet 2 of 2)FIGURE F-8. 40-amp input connector assembly. (sheet 1 of 2)FIGURE F-8. 40-amp input connector assembly. (sheet 2 of 2)FIGURE F-9. MS90563-3C COVER, ELECTRICAL CONNECTOR MS90555C32413S CONNECTOR, ELECTRICAL RECEPTACLE GASKET M39029/49-331 CONTACT, ELECTRICAL SOCKET (A, B, C, N) M5086/2-4-9 WIRE, ELECTRICAL (A, B, C, N) M5086/2-8-9 WIRE, ELECTRICAL (G) M39029/49-329 CONTACT, ELECTRICAL SOCKET (G) MS3348-6-8L REDUCER, ELECTRICAL CONTACT (G) 40/60-amp output connector assembly. (sheet 1 of 2)FIGURE F-9. 40/60-amp connector assembly. (sheet 2 of 2) FIGURE F-10. 60-amp input connector assembly. (sheet 1 of 2)FIGURE F-10. 60-amp input connector assembly. (sheet 2 of 2)FIGURE F-11. 60-amp output connector assembly, (sheet 1 of 2)FIGURE F-11. 60-amp output connector assembly. (sheet 2 of 2)FIGURE F-12. 20amp output connector assembly. (sheet 1 of 2)FIGURE F-12. 20-amp output connector assembly. (sheet 2 of 2) FIGURE F-13. 20-amp output connector assembly. (sheet 1 of 2)FIGURE F-13. 60-amp output connector assembly. (sheet 2 of 2)FIGURE F-14. 20-amp output connector assembly. (sheet 1 of 2) FIGURE F-14. 20-amp output connector assembly. (sheet 2 of 2)FIGURE F-38 MS90557C54213S CONNECTOR, ELECTRICAL SOCKET (P1) M39029/49-335 CONTACT, ELECTRICAL SOCKET (P1-A, B, C, N) M39029/49-332 CONTACT, ELECTRICAL SOCKET (P1-G1, G2, G3, G4) M23053/5-114-4 SLEEVING, INSULATION, HEAT SHRINK CO-04HDE (4/0000-4/4R) 2380 CABLE TAG, WARNING F-15. 200-amp, 4-ft (1.2m) pigtail cable. (sheet 1 of 3)FIGURE F-15. 200-amp, 4-ft (1.2m) pigtail cable. (sheet 2 of 3)FIGURE F-15. 200-amp, 4-ft (1.2m) pigtail cable. (sheet 3 of 3)FIGURE F-16. 100-amp, 4-ft (1.2m) pigtail cable. (sheet 1 of 3)FIGURE F-16. 100-amp, 4-ft (1.2m) pigtail cable. (sheet 2 of 3)FIGURE F-16. 100-amp, 4-ft (1.2m) pigtail cable. (sheet 3 of 3)FIGURE F-17. 40/60-amp, 4-ft (1.2m) pigtail cable. (sheet 1 of 3)FIGURE F-17. 40/60-amp, 4-ft (1.2m) pigtail cable. (sheet 2 of 3)FIGURE F-17. 40/60-amp, 4-ft (1.2m) pigtail cable. (sheet 3 of 3)FIGURE MS3102R16-10S CONNECTOR, ELECTRICAL RECEPTACLE (P1) M90929/49-331 CONTACT, ELECTRICAL SOCKET (P1-A, N) MS3348-6-8L BUSHING REDUCING # 6 AWG (P1-G) M39029/38-329 CONTACT, ELECTRICAL SOCKET (P1-G) M2305315-112-4 SLEEVING, INSULATION, HEAT SHRINK C0-02HDF (2/4-2/8R) 1290 CABLE TAG, WARNING F-18. 60-amp, 4-ft (1.2m) pigtail cable. (sheet 1 of 3)FIGURE F-18. 60-amp, 4-ft (1.2m) pigtail cable. (sheet 2 of 3)FIGURE F-18. 60-amp, 4-ft (1.2m) pigtail cable. (sheet 3 of 3) FIGURE F-19. 200-amp, 25-ft (7.6m) service/feeder cable. (sheet 1 of 3)FIGURE F-19. 200-amp, 25-ft (7.6m) service/feeder cable. (sheet 2 of 3)FIGURE F-19. 200-amp, 25-ft (7.6m) service/feeder. (sheet 3 of 3)FIGURE F-20. 100-amp, 50-ft (15.2m) service/feeder cable. (sheet 1 of 3) FIGURE F-20. 100-amp, 50-ft (15.2m) F-54 service/feeder cable. (sheet 2 of 3)FIGURE F-20. 100-amp, 50-ft (15.2m) service/feeder. (sheet 3 of 3)FIGURE F-21. 40/60-amp, 50-ft (15.2m) service/feeder cable. (sheet 1 of 3)FIGURE F-21. 40/60-amp, 50-ft (15.2m) service/feeder cable. (sheet 2 of 3)FIGURE F-21. 40/60-amp, 50-ft (15.2m) service/feeder. (sheet 3 of 3) FIGURE F-22. 60-amp, 100-ft (30.5m) service/feeder cable. (sheet 1 of 3) FIGURE F-22. 60-amp, 100-ft (30.5m) service/feeder cable. (sheet 2 of 3)FIGURE F-22. 60-amp, 100-ft (30.5m) service/feeder. (sheet 3 of 3)FIGURE F-23. 20-amp, 15-ft (4.57m) extension cable. (sheet 1 of 3)FIGURE F-23. 20-amp, 15-ft (4.57m) extension cable. (sheet 2 of 3)FIGURE F-23. 20-amp, 15-ft (4.57m) extension cable. (sheet 3 of 3)FIGURE F-24. 20-amp, 25-ft (7.62m) extension cable. (sheet 1 of 3)FIGURE F-24. 20-amp, 25-ft (7.62m) extension cable. (sheet 2 of 3)FIGURE F-24. 20-amp, 25-ft (7.62m) extension cable. (sheet 3 of 3)FIGURE F-25. 20-amp, 50-ft (15.24m) extension cable. (sheet 1 of 3) FIGURE F-25. 20-amp, 50-ft (15.24m) extension cable. (sheet 2 of 3)FIGURE F-25. 20-amp, 50-ft (15.24m) extension cable. (sheet 3 of 3)FIGURE F-26. PDISE 200-amp, input connector assembly. (sheet 1 of 2)FIGURE F-26. PDISE 200-amp input connector assembly. (sheet 2 of 2)FIGURE F-27. PDISE 100-amp, input connector assembly. (sheet 1 of 2) FIGURE F-27. PDISE 100-amp input connector assembly. (sheet 2 of 2) FIGURE F-28. PDISE 100-amp, output connector assembly. (sheet 1 of 2)M200A/P ,CONNECTOR J4M200 A/P, CONNECTOR J11FIGURE F-29. PDISE 40-amp, input connector assembly. (sheet 1 of 2)FIGURE F-29. PDISE 40-amp input connector assembly. (sheet 2 of 2)FIGURE F-30. PDISE 40/60-amp, output connect or assembly. (sheet 1 of 2)M200 A/P, CONNECTOR J7 AND J9M1OO A/P, CONNECTOR J3 AND J5 FIGURE F-31. PDISE 60-amp, input connector assembly. (sheet 1 of 2)FIGURE F-31. PDISE 60-amp input connector assembly. (sheet 2 of 2)FIGURE F-32. PDISE 60-amp, output connector assembly. (sheet 1 of 2)FIGURE F-32. PDISE 60-amp output connector assembly. (sheet 2 of 2) FIGURE F-33. PDISE 20-amp, output connector assembly. (sheet 1 of 2)M40 A/P, CONNECTORS J3, J5, J7, J9, J11 AND J13M60 A/P, CONNECTORS J4, J6 AND J8FIGURE F-34. PDISE 20-amp, output connector assembly. (sheet 1 of 2)FIGURE F-34. PDISE 20-amp output connector assembly. (sheet 2 of 2) FIGURE F-35. PDISE 20-amp, output connector assembly. (sheet 1 of 2)FIGURE F-35. PDISE 20-amp output connector assembly. (sheet 2 of 2)APPENDIX G TORQUE LIMITSTable G-2. SELF-LOCKING NUT BREAKAWAY TORQUE VALUESGLOSSARY - TM-9-6150-226-13_324Section II. DEFINITION OF UNUSUAL TERMS (continued)