TM 9-6115-730-24
0009
TROUBLESHOOTING USING GSC FAULT CODES - Continued
NOTE
This fault code indicates that the ECM has detected an internal power supply or memory problem
that can not be repaired.
SYMPTOM
28.
CID 254 E FMI 12
MALFUNCTION
ECM Self Test.
FMI 12 - Failed Component.
CORRECTIVE ACTION
STEP 1.
If the ECM fails Self Test, replace ECM (WP 0082).
STEP 2.
Load correct flash file into ECM (WP 0013, SYMPTOM 9).
STEP 3.
Verify the ECM passes Self Test.
SYMPTOM
29.
CID 261 E FMI 13
MALFUNCTION
FMI 13 - Device is Not Calibrated.
CORRECTIVE ACTION
Perform Engine Timing Calibration (WP 0013, SYMPTOM 8).
0009-23