TM 9-6115-729-24
0009
TROUBLESHOOTING USING GSC FAULT CODES - Continued
NOTE
This fault code indicates that the ECM has detected an internal power supply or memory problem
that can not be repaired.
SYMPTOM
31.
CID 254 E FMI 12
MALFUNCTION
ECM self test.
FMI 12 - Failed Component.
CORRECTIVE ACTION
STEP 1.
If the ECM fails Self Test, replace ECM (WP 0084).
STEP 2.
Load correct flash file into new ECM (WP 0013, SYMPTOM12).
STEP 3.
Verify the ECM passes Self Test.
SYMPTOM
32.
CID 261 E FMI 13
MALFUNCTION
FMI 13 - Device is not Calibrated.
CORRECTIVE ACTION
Perform Engine Timing Calibration (WP 0013, SYMPTOM 11).
NOTE
These failures are caused by either a failed sensor or a problem with the wiring.
SYMPTOM
33.
CID 262 E FMI 03
CID 262 E FMI 04
MALFUNCTION
5 V sensor power supply.
FMI 03 - Voltage Above Normal.
FMI 04 - Voltage Below Normal.
0009-27