TM 9-6115-729-24
0005
Troubleshooting Procedure
Malfunction/Symptom
22.
CID 168 E FMI 02 Electrical System Voltage Erratic, Intermittent, or Incorrect Signal ...................... WP 0009
CID 168 E FMI 03 Electrical System Voltage Voltage Above Normal ................................................ WP 0009
CID 168 E FMI 04 Electrical System Voltage Voltage Below Normal ................................................ WP 0009
23.
CID 169 E FMI 01 Engine Oil Maintenance Required (Active)........................................................... WP 0009
24.
CID 170 E FMI 01 Fuel Filter Change Required (Active) ................................................................... WP 0009
25.
CID 172 E FMI 00 Inlet Air Temperature Sensor Data is Valid but Data is Above Normal
Operating Range (Logged) ................................................................................................................. WP 0009
CID 172 E FMI 03 Inlet Air Temperature Sensor Voltage Below Normal Voltage Open/
Short to Batt+. ..................................................................................................................................... WP 0009
CID 172 E FMI 04 Inlet Air Temperature Sensor Voltage Below Normal Voltage Short to Ground... WP 0009
CID 172 E FMI 11 Inlet Air Temperature Sensor Failure Mode is Not Identifiable
(Mechanical Failure) (Logged) ............................................................................................................ WP 0009
26.
CID 175 FMI 02 Engine Oil Temperature Sensor Erratic, Intermittent, or Incorrect
Signal (Logged)................................................................................................................................... WP 0009
CID 175 FMI 03 Engine Oil Temperature Sensor Voltage Above Normal Voltage Open/Short
to Batt+................................................................................................................................................ WP 0009
CID 175 FMI 04 Engine Oil Temperature Sensor Voltage Below Normal Voltage
Short to Ground .................................................................................................................................. WP 0009
27.
CID 190 FMI 02 Magnetic Pickup Unit Erratic, Intermittent, or Incorrect............................................ WP 0009
CID 190 FMI 03 Magnetic Pickup Unit Voltage Above Normal (Logged) ........................................... WP 0009
28.
CID 190 E FMI 02 Primary Engine Speed/Timing Sensor Erratic, Intermittent, or Incorrect
Signal (Logged) ............................................................................................................................. WP 0009
CID 190 E FMI 11 Primary Engine Speed/Timing Sensor Failure Mode is Not Identifiable
(Mechanical Failure) (Logged) ............................................................................................................ WP 0009
29.
CID 248 FMI 09 CAT Data Link Abnormal update ............................................................................. WP 0009
30.
CID 253 E FMI 02 Personality Module Mismatch Erratic, Intermittent, or Incorrect Signal ................ WP 0009
31.
CID 254 E FMI 12 ECM Self Test Failed Component ........................................................................ WP 0009
32.
CID 261 E FMI 13 Engine Timing Calibration Device is Not Calibrated ............................................. WP 0009
33.
CID 262 E FMI 03 5 V Sensor Power Supply Voltage Above Normal................................................ WP 0009
CID 262 E FMI 04 5 V Sensor Power Supply Voltage Below Normal ................................................ WP 0009
34.
CID 264 E FMI 03 E-Stop Shutdown Voltage Above Normal (Active) ............................................... WP 0009
35.
CID 268 FMI 02 GSC Electronic Control Erratic, Intermittent, or Incorrect Signal ............................. WP 0009
36.
CID 269 FMI 03 GSC 8V Sensor Power Supply Voltage Above Normal ........................................... WP 0009
CID 269 FMI 04 GSC 8V Sensor Power Supply Voltage Below Normal............................................ WP 0009
37.
CID 273 FMI 03 Turbo Outlet Pressure Sensor Voltage Above Normal ............................................ WP 0009
CID 273 FMI 04 Turbo Outlet Pressure Sensor Voltage Below Normal............................................. WP 0009
38.
CID 274 FMI 02 Atmospheric Pressure Sensor Erratic, Intermittent, or Incorrect Signal .................. WP 0009
39.
CID 274 FMI 03 Atmospheric Pressure Sensor Voltage Above Normal ............................................ WP 0009
CID 274 FMI 04 Atmospheric Pressure Sensor Voltage Below Normal............................................. WP 0009
40.
CID 334 FMI 02 Spare Output (P7-36) Erratic, Intermittent, or Incorrect Signal ................................ WP 0009
CID 334 FMI 03 Spare Output (P7-36) Voltage Above Normal.......................................................... WP 0009
CID 334 FMI 04 Spare Output (P7-36) Voltage Below Normal .......................................................... WP 0009
41.
CID 336 E FMI 02 ENGINE CONTROL Switch (ECS) Erratic, Intermittent, or Incorrect Signal ........ WP 0009
42.
CID 342 E FMI 02 Secondary (Bottom) Engine Speed/Timing Sensor Erratic, Intermittent,
or Incorrect Signal (Logged) ............................................................................................................... WP 0009
CID 342 E FMI 11 Secondary (Bottom) Engine Speed/Timing Sensor Failure mode is not
identifiable (Mechanical Failure) (Logged) ......................................................................................... WP 0009
43.
CID 360 E FMI 01 Low Engine Oil Pressure Warning (Active & Logged) Data is Valid But
Data is Below Normal Operating Range............................................................................................. WP 0009
CID 360 E FMI 02 Low Engine Oil Pressure Derate (Active & Logged) Erratic, Intermittent,
or Incorrect Signal............................................................................................................................... WP 0009
CID 360 E FMI 03 Low Engine Oil Pressure Shutdown (Active & Logged)
Voltage Above Normal ........................................................................................................................ WP 0009
0005-3