ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
Section IV. REMARKS
REMARKS
CODE
REMARKS
A
There are two generator set models covered by this Maintenance Allocation Chart. MEP-
501A is a 2 kW, 28 VDC Military Tactical Generator Set. MEP-531A is a 2 kW, 120 VAC
Military Tactical Generator Set.
B
Repair of the frame at the Organizational level limited to replacement of damaged
threaded inserts.
C
Repair of the engine/alternator at the Organizational level is limited to the replacement of
ground straps, wiring, and data plates, etc.
D
Repair of the diesel engine at the Organizational level is limited to the replacement of the
governor regulator bracket, recoil starter, engine oil strainer, valve cover, and starter
(MEP-501A).
E
Repair of the cylinder block installation at the Organizational level is limited to the
replacement of oil fill cap and oil drain plugs.
F
Adjustment of the cylinder head installation consists of checking torque on cylinder head
nuts and valve adjustment.
G
Repair of the lube oil pump and governor at the Organizational level is limited to the
replacement of the regulator bracket and external lever.
H
Repair of the regulator bracket is limited to the replacement of a spring.
I
Replace starter motor at Direct Support for MEP-531A since the alternator must also be
removed.
J
Repair of the alternator at the Organizational level is limited to the replacement of the
brushes (MEP-531A).
K
All control panel repairs can be performed at the Organizational level except for the
replacement of the governor control unit and the voltage regulator.
L
EMI filter installed in MEP-531A only.