ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
Table 1-1. Leading Particulars Continued
MEP-531A:
Manufacturer ...........................................................Dewey Electronics Corporation
Type ...........................................................................Rotating field synchronous
Load Capacity .................................................................................................. 2 kW
Voltage Output ..................................................................... 120 VAC single phase
2 wire and ground (bonded to frame)
Power Factor ....................................................................................................... 1.0
Load Recovery Time (Voltage):
NL to FL..............................................................................................3.0 seconds
FL to NL..............................................................................................3.0 seconds
NL to FL..............................................................................................4.0 seconds
FL to NL..............................................................................................5.0 seconds
Cooling ...................................................................................................... forced air
Lubrication Requirements ................................................................................ none
Drive Type ......................................................................................... direct coupling
Duty Classification...................................................................................continuous
MEP-501A:
Manufacturer ...........................................................................Balmar Products Inc.
Type .................................................................................. Brush AC rectified to DC
Load Capacity .................................................................................................. 2 kW
Voltage Output ............................................................................................ 28 VDC
Load Recovery Time (Voltage):
NL to FL..............................................................................................1.0 seconds
FL to NL..............................................................................................0.5 seconds
Cooling ...................................................................................................... forced air
Lubrication Requirements ................................................................................ none
Drive Type ......................................................................................... direct coupling
Duty Classification...................................................................................continuous
i. Safety Devices.
Low Engine Oil Pressure:
Trip Pressure (Range)............................................................................... 12-18 psi
Voltage Rating ............................................................................................ 24 VDC
Current Rating .............................................................................................. 5 amps
Method ...............................................................Electrically-operated solenoid with
mechanical link to fuel governor
1-10