ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
2-20
TABLE 2-5. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
(continued)
B-BEFORE
D-DURING
A-AFTER
Interval
Item
No.
B
D
A
Item to
be inspected
Procedures
Check for and have
Repaired or adjusted
as necessary
Equipment is
not ready/
available if:
__________
WARNING
High voltage is produced when this
generator set is in operation. Make
sure unit is completely shut down and
free of any power source before
attempting any repair or maintenance
on the unit. Failure to comply can
cause injury or death to personnel.
19
Output Box
Assembly
Check for loose or damaged wiring or
cables (Figure 1-2).
Loose or damaged
wiring or cables.
20
Load Output
Terminal Board
Check output terminals for damaged or
missing hardware (26, Figure 1-30 sheet
2)
Damaged or missing
hardware.
DCS CONTROL
BOX ASSEMBLY
21
Controls and
Indicators
Check all controls and indicators for
damaged or missing parts. Ensure relays
are securely plugged in.
Controls or indicators
with damaged or
missing parts.
Ensure all indicators are operating
properly.
CIM inoperative.
22
Control Box Wiring
Harness
Check for loose or damaged wiring.
Loose or damaged
wires.
23
Parallel Operation
Cable
If required for generator set operation,
inspect parallel operation cable for
damage.